APPLICATION

The product is suitable for power transmission and distribution lines with rated power frequency voltage up to and including 0.6/1KV.
Operating Performance
1). Rated power frequency voltage Uo/U: 0.6/1KV.
2). Max. Permissible continuous operating temperature of conductor: 90℃
3). Max. Short-circuit temperature of the conductor shall not exceed: (5S maximum duration) 250℃
4). The ambient temperature under installation should not below 0℃
5). The bending radius of a cable should not be less than 15 times of the cable diameter.
6). The test voltage (A.C.): 3.5kV/5min.
7). The flame-retardant properties of cable comply with grade A, B, C of IEC60332.

Low voltage XLPE or PVC insulated power cable L07

STANDARD & REFERENCES

IEC 60502-1. Or BS, DIN, ICEA standard as customer request.

IEC 60228

IEC 60332

CONSTRUCTIONS

Low voltage XLPE or PVC insulated power cable L06
Component Material / Description
Conductor Solid or stranded copper, aluminum
Insulation Cross-linked polyethylene (XLPE) or PVC
Filler Polypropylene filament with lapped binding tape
Inner Sheath Polyvinyl chloride (PVC) – Black or as requested
Armor Galvanized steel wire or steel tape
Core-covering Binding tape
Outer Sheath Polyvinyl chloride (PVC) – Black or as requested

PARAMETERS

TypeNo. of coresNom. Cross-section of conductor
Copper conductorAluminum conductor(mm2)
YJV  YJY11.5-800
YJLV  YJLY2.5-800
YJV22  YJV23YJLV22  YJLY2310-800
YJV  YJY21.5-300
YJLV  YJLY2.5-300
YJV22  YJV23YJLV22  YJLY234.0-300
YJV32  YJV33YJLV32  YJLY3310-300
YJV  YJY31.5-400
YJLV  YJLY2.5-400
YJV22  YJV23YJLV22  YJLY234.0-400
YJV32  YJV33YJLV32  YJLY3310-400
YJV  YJY41.5-400
YJLV YJLY2.5-400
YJV22  YJV23YJLV22  YJLY234.0-400
YJV32  YJV33YJLV32  YJLY3310-400
YJV  YJY3+11.5-400
YJLV  YJLY4.0-400
YJV22  YJV23YJLV22  YJLY234. 0-400
YJV32  YJV33YJLV32  YJLY3310-400
YJV  YJY51.5-400
YJLV  YJLY2.5-400
YJV22  YJV23YJLV22  YJLY234.0-400
YJV32  YJV33YJLV32  YJLY3310-400
YJV  YJY4+11.5-400
YJLV  YJLY4.0-400
YJV22  YJV23YJLV22  YJLY234. 0-400
YJV32  YJV33YJLV32  YJLY3310-400
YJV  YJY3+21.5-400
YJLV  YJLY4.0-400
YJV22  YJV23YJLV22  YJLY234. 0-400
YJV32  YJV33YJLV32  YJLY3310-400
The armoured single core cables are used for D.C. system only. As for A.C. system,non-magnetic armour material should be used, or a magnetic isolation should be applied.

Please contact engineer to Get complate specification.

ASK Us A Questions

Get Free Quote

Please do not hesitate to contact our cable engineer, they will be back to you in next 8 hours.