Home / Product / Low voltage XLPE or PVC insulated power cable


CU or AL conductor, XLPE or PVC insulation, PVC or LSZH sheath, with or without steel wire or steel tape armor, flame retardant, sun resistant.
The product is suitable for power transmission and distribution lines with rated power frequency voltage up to and including 0.6/1KV.
Operating Performance
1). Rated power frequency voltage Uo/U: 0.6/1KV.
2). Max. Permissible continuous operating temperature of conductor: 90℃
3). Max. Short-circuit temperature of the conductor shall not exceed: (5S maximum duration) 250℃
4). The ambient temperature under installation should not below 0℃
5). The bending radius of a cable should not be less than 15 times of the cable diameter.
6). The test voltage (A.C.): 3.5kV/5min.
7). The flame-retardant properties of cable comply with grade A, B, C of IEC60332.
IEC 60502-1. Or BS, DIN, ICEA standard as customer request.
IEC 60228
IEC 60332
| Component | Material / Description |
|---|---|
| Conductor | Solid or stranded copper, aluminum |
| Insulation | Cross-linked polyethylene (XLPE) or PVC |
| Filler | Polypropylene filament with lapped binding tape |
| Inner Sheath | Polyvinyl chloride (PVC) – Black or as requested |
| Armor | Galvanized steel wire or steel tape |
| Core-covering | Binding tape |
| Outer Sheath | Polyvinyl chloride (PVC) – Black or as requested |
| Type | No. of cores | Nom. Cross-section of conductor | |
| Copper conductor | Aluminum conductor | (mm2) | |
| YJV YJY | – | 1 | 1.5-800 |
| – | YJLV YJLY | 2.5-800 | |
| YJV22 YJV23 | YJLV22 YJLY23 | 10-800 | |
| YJV YJY | – | 2 | 1.5-300 |
| – | YJLV YJLY | 2.5-300 | |
| YJV22 YJV23 | YJLV22 YJLY23 | 4.0-300 | |
| YJV32 YJV33 | YJLV32 YJLY33 | 10-300 | |
| YJV YJY | – | 3 | 1.5-400 |
| – | YJLV YJLY | 2.5-400 | |
| YJV22 YJV23 | YJLV22 YJLY23 | 4.0-400 | |
| YJV32 YJV33 | YJLV32 YJLY33 | 10-400 | |
| YJV YJY | – | 4 | 1.5-400 |
| – | YJLV YJLY | 2.5-400 | |
| YJV22 YJV23 | YJLV22 YJLY23 | 4.0-400 | |
| YJV32 YJV33 | YJLV32 YJLY33 | 10-400 | |
| YJV YJY | – | 3+1 | 1.5-400 |
| – | YJLV YJLY | 4.0-400 | |
| YJV22 YJV23 | YJLV22 YJLY23 | 4. 0-400 | |
| YJV32 YJV33 | YJLV32 YJLY33 | 10-400 | |
| YJV YJY | – | 5 | 1.5-400 |
| – | YJLV YJLY | 2.5-400 | |
| YJV22 YJV23 | YJLV22 YJLY23 | 4.0-400 | |
| YJV32 YJV33 | YJLV32 YJLY33 | 10-400 | |
| YJV YJY | – | 4+1 | 1.5-400 |
| – | YJLV YJLY | 4.0-400 | |
| YJV22 YJV23 | YJLV22 YJLY23 | 4. 0-400 | |
| YJV32 YJV33 | YJLV32 YJLY33 | 10-400 | |
| YJV YJY | – | 3+2 | 1.5-400 |
| – | YJLV YJLY | 4.0-400 | |
| YJV22 YJV23 | YJLV22 YJLY23 | 4. 0-400 | |
| YJV32 YJV33 | YJLV32 YJLY33 | 10-400 | |
| The armoured single core cables are used for D.C. system only. As for A.C. system,non-magnetic armour material should be used, or a magnetic isolation should be applied. | |||
Please contact engineer to Get complate specification.
Please do not hesitate to contact our cable engineer, they will be back to you in next 8 hours.